MD280/MD280N User Manual Parameter Description
- 133 -
Where,
SB1: Running enable button and stop button
SB2: Forward rotation button
SB3: Reverse rotation button
DIn ranges between DI1 and DI5. In this case, it shall define the
corresponding terminal function setting as No.3 function “Three-line
Running Control”.
3: Three-line running mode 2: DIn terminal serves as running enable
terminal, and the running command is given by the FWD terminal, while the
running direction depends on the status of REV terminal. The stop
command is performed by disconnecting the DIn terminal. The descriptions
on the terminal running command are as shown in Fig. 6-8:
K
Running Direction
Selection
0 Forward Rotation
1 Reverse Rotation
Fig 6-7 Three Mode Running Mode 2
MD280
FWD
COM Digital public terminal
REV
Digital input terminal
Digital input terminal
DIn Three-line mode running
control terminal
SB1
SB2
SB3