Safety and Precautions   MD280/MD280N User Manual 
when they are burnt.Emission of toxic gas may be generated when the 
plastic parts are burnt.    Please dispose the inverter as industrial wastes.   
1.2.14 Adaptable Motor   
1) The standard adaptable motor is four-pole squirrel-cage asynchronous 
induction motor. If such motor is not available, be sure to select adaptable 
motors in according to the rated current of the motor. In applications where 
drive permanent magnetic synchronous motor is required, please consult 
our company. 
2) The cooling fan and the rotor shaft of the non-frequency-conversion 
motor adopt coaxial connection. When the rotating speed is reduced, the 
heat sinking effect will be poorer. Therefore, a powerful exhaust fan shall 
be installed, or the motor shall be replaced with frequency conversion 
motor to avoid the overheating of the motor. 
3) Since the inverter has built-in standard parameters of the adaptable 
motors, it is necessary to perform motor parameter identification or modify 
the default values so as to comply with the actual values as much as 
possible, or it may affect the running effect and protection performance;   
4) The short circuit of the cable or motor may cause alarm or explosion of 
the inverter.    Therefore, please conduct insulation and short circuit test on 
the newly installed motor and cable. Such test shall also be conducted 
during routine maintenance.  Please note that the inverter and the test 
part shall be completely disconnected during the test.   
 
 
 
 
 
 
 
 
 
 
 