Loading...
Parameter Description MD280/MD280N User Manual
- 186 -
F
B
-
2
6
Input
termi
nal
statu
s
upon
fault
This value is
a decimal
number. It
displays the
status of all
the digital
terminals of
the last fault
in the
following
sequence:
BIT7
BIT
6
BIT
5
BIT
4
BIT
3
BIT
2
BIT
1
BIT
0
reserved reserv
ed
reserv
ed
DI5 DI4 DI3 DI2 DI1
It is displayed in decimal numbers corresponding to the
status of each digit. When the input terminal is ON, the
corresponding value is 1. When the input terminal is
OFF, the value is 0. With this value, the user can know
the current digital input signal.