Inovance MD280 Series - Inverter Status Monitoring Parameters

Inovance MD280 Series
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Stop/stop parameter:
Parameter addr. Parameter description
1000H
Communication setup value(-10000 to
10000)( Decimal)
1001H Running frequency
1002H Bus voltage
1003H Output voltage
1004H Output current
1005H Output power
1006H Reserved
1007H Reserved
1008H DI input status
1009H DO output status
100AH AI1 voltage
100BH AI1 voltage
100CH Reserved
100DH Counting value input
100EH Length value input
100FH Load speed
1010H PID setup
1011H PID feedback
1012H PLC process
Caution:
For the patameters of this part, the communication setup frequency value is
the percentage of the maximum frequency (-100.00% to 100.00%), which can
be communication read and write.The other parameters can be read but not
wrote.