Data format Factory
default value
0
0 No check:data format<8,N,2>
1 Even parity check :data format
<8,E,1>
FA-01
Setup
range
2 Odd parity check : data
format<8,O,1>
When use the parity or odd parity, the length of each byte is 11 bits, which
includes a start bit, 8 data bits, 1 parity bit and one end bit.
When use the no check, the length of each byte is 11 bits, which includes a
start bit, 8 data bits, 1 parity bit and 2 end bits. The data format of the host
computer and the inverter setup must be consistent, otherwise,
communication is impossible.
Local addr.
Factory
default value
1
FA-02
Setup range 0 to 247,0 is broadcast address
The function code used to identify the local address of the inverter.The local
address is unique (except the broadcast address), which can realize the
broadcast function of host computer.
Caution: When the local address is set to zero, that is the broadcast address,
which can only receive and perform the broadcast address of host computer
but not respond to the host computer.
Response delay Factory default
value
2ms
FA-03
Setup range 0 to 20ms
Response delay: It refers to the interval time from the inverter finishes
receiving data to sending data to the host machine.If the response delay is
less than the system processing time, then the response based on the time
delay of the system processing time.If the response delay is more than the
system processing time, after the system processes the data, it should be
delayed to wait until the response delay time is up, then sending data to host
machine.