Para. No. Para. Name Setting Range Default Property Page
A2-07 Rotor resistance WRȍ$&GULYH
SRZHUN:
WRȍ$&
drive power > 55 kW)
Auto-tuning
dependent
ƾ
1
7
0
A2-08 Leakage inductive reactance 0.01 to 655.35 mH (AC
GULYHSRZHUN:
0.001 to 65.535 mH (AC
drive power > 55 kW)
Auto-tuning
dependent
ƾ
1
7
1
A2-09 Mutual inductive reactance 0.1 to 6553.5 mH (AC drive
SRZHUN:
0.01 to 655.35 mH (AC
drive power > 55 kW)
Auto-tuning
dependent
ƾ
1
7
1
A2-10 No-load current 0.01 A to A2-03 (AC drive
SRZHUN:
0.1 A to A2-03 (AC drive
power > 55 kW)
Auto-tuning
dependent
ƾ
1
7
1
A2-37 Motor auto-tuning method
selection
0: No auto-tuning
1: Static auto-tuning 1
2: Dynamic auto-tuning
3: Static auto-tuning 2
0
ƾ
-
A2-62 Motor 2 control mode 2: V/F control 2
ƾ
-
A2-63 Motor 2 acceleration/deceleration
time selection
0: The same motor 1
2: Acceleration/deceleration
time 2
3: Acceleration/deceleration
time 3
4: Acceleration/deceleration
time 4
0
ƿ
-
A2-64 Motor 2 torque boost ¿[HGWRUTXHERRVW
0.1% to 30.0%
Model
dependent
ƿ
-
A2-66 Motor 2 oscillation suppression
gain
0 to 100 40
ƿ
-
Group A5: Control Optimization
A5-00 DPWM switchover frequency
upper limit
5.00 Hz to max. frequency 8.00 Hz
ƿ
1
5
2
A5-01 PWM modulation pattern 0: Asynchronous
modulation
1: Synchronous modulation
0
ƿ
1
5
2
A5-02 Dead zone compensation mode
selection
0: No compensation
1: Compensation mode 1
1
ƿ
-
A5-03 Random PWM depth 0 to 10 0
ƿ
1
5
2
A5-04 Overcurrent fast prevention 0: Disabled
1: Enabled
1
ƿ
1
5
9
A5-05 0D[RXWSXWYROWDJHFRHI¿FLHQW 100% to 110% 105%
ƾ
1
5
2
A5-06 Undervoltage threshold 210 to 420 V 350 V
ƿ
1
5
9
A5-08 Dead-zone time adjustment 100% to 200% 150%