EasyManua.ls Logo

INSYS EloStar time - Page 17

INSYS EloStar time
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EloStar time
Handbuch
Version 1.03
17
Activation of IO functions
Notes:
After activation, the following inputs/outputs are queried or actuated.
Activation or deactivation can only be performed by the master.
The activation or deactivation is saved in the event log.
*9*
Enter program number 9
123456 *
1
Enter the master code
11*
1
Enter the function number (e.g. 11)
2nd digit => outputs
1st digit => inputs
Explanation of the function numbers:
Inputs:
1st digit
0
= No function
1
= Door switch (IN1)
2
= Door switch (IN1), release/blocking (IN2)
3
= Release/blocking (IN1)
Outputs:
2nd digit
0
= No function
1
= Deadbolt status (OUT1)
2
= Silent alarm (OUT1)
3
= Silent alarm (OUT1), deadbolt status (OUT2)
4
= Silent alarm (OUT1), end of opening delay (OUT2)
5
= Deadbolt state (OUT1), end of opening delay (OUT2)
Deleting I/O functions
*9*
Enter program number 9
123456 *
1
Enter the master code
00*
1
Delete = 00 *