EloStar time
Handbuch
Version 1.03
19
3.12.3. Automatic locking with the door switch
Notes:
With the function “Automatic locking via door switch”, the electronic lock can
be automatically locked by actuating a door or boltwork switch.
If the door switch is not opened within 15 seconds after the code is entered
and the lock is opened, the electronic lock locks again automatically.
The “Automatic locking” function can also be programmed with the PC
software CombiComm.
Activation of the function “Automatic locking via door switch”
*9*
Enter program number 9
123456 *
1
Enter the master code
10*
1
Enter the function number (e.g. 10)
Connect the door switch to IN1
3.12.4. External release / blocking
Notes:
The electronic lock can be blocked or released by an external signal, e.g. by a
burglar alarm system, via this input contact. The lock can then no longer be
operated by a user.
The function can either be programmed to IN1 or IN2, see function numbers.
Activation of the function “External blocking / release”
*9*
Enter program number 9
123456 *
1
Enter the master code
30*
1
Enter the function number (e.g. 30)
Connect the blocking signal to IN1