Intel Desktop Board D915GLVG Technical Product Specification 
78   
Table 40.  BIOS Error Messages (continued) 
Error Message  Explanation 
Update OK!  NVRAM was invalid and has been updated. 
Updated Failed  NVRAM was invalid but was unable to be updated. 
Keyboard Error  Error in the keyboard connection.  Make sure keyboard is 
connected properly. 
KB/Interface Error  Keyboard interface test failed. 
Memory Size Decreased  Memory size has decreased since the last boot.  If no memory was 
removed then memory may be bad. 
Memory Size Increased  Memory size has increased since the last boot.  If no memory was 
added there may be a problem with the system. 
Memory Size Changed  Memory size has changed since the last boot.  If no memory was 
added or removed then memory may be bad. 
No Boot Device Available  System did not find a device to boot. 
Off Board Parity Error  A parity error occurred on an off-board card.  This error is followed 
by an address. 
On Board Parity Error  A parity error occurred in onboard memory.  This error is followed 
by an address. 
Parity Error  A parity error occurred in onboard memory at an unknown 
address. 
NVRAM/CMOS/PASSWORD cleared by 
Jumper 
NVRAM, CMOS, and passwords have been cleared.  The system 
should be powered down and the jumper removed. 
<CTRL_N> Pressed  CMOS is ignored and NVRAM is cleared.  User must enter Setup.