28
Registration or change of Remote Control
Settings Result
Remote Control Registration
ENTER + MASTER
PASSWORD
Factory default:
1234
ENTER + 60 +
USER + ENTER
Trigger Control Key
Note:
»
User Number = 00 to 61
»
3 short beeps after command = Re-
gistered Control
»
1 long beep after command = Con-
trol Not Registered
Delete Remote Control
ENTER + MASTER
PASSWORD
Factory default:
1234
ENTER + 70 + User + ENTER
Note:
»
User Number = 00 to 61
Remote Control Registration
ENTER +
INSTALLER
PASSWORD
Factory default:
9090
ENTER + 60 +
USER + ENTER
Trigger Control Key
Note:
»
User Number = 00 to 61
»
3 short beeps after command = Re-
gistered Control
»
1 long beep after command = Con-
trol Not Registered
Delete Remote Control
ENTER +
INSTALLER
PASSWORD
Factory default:
9090
ENTER + 70 + User + ENTER
Note:
»
User Number = 00 to 61
Registration or change of Wireless Sensor
Settings Result
Wireless Sensor
Registration
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 61 + ZONE
+ ENTER
Trigger Sensor
Note:
»
Zone = 25 to 48
»
3 short beeps after command
= Registered Sensor
»
1 long beep after command =
Sensor Not Registered
Delete
Wireless Sensor
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 71 + ZONE/
SECTOR + ENTER
Note:
Zone = 25 to 48
Zone Functions
Enable/Disable zones
KEY ADDRESS Key
Key 1 2 3 4 5 6 7 8
Key Result
Enable
Disable
Enter
300 Enter Zones 1 to 8 1 2 3 4 5 6 7 8
Enter
Note:
Zone = 01
to 48
301 Enter Zones 9 to 16 9 10 11 12 13 14 15 16
302 Enter Zones 17 to 24 17 18 19 20 21 22 23 24
303 Enter Zones 25 to 32 25 26 27 28 29 30 31 32
304 Enter Zones 33 to 40 33 34 35 36 37 38 39 40
305 Enter Zones 41 to 48 41 42 43 44 45 46 47 48