Number of Rings Setting
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 12 + RINGS + ENTER
Note:
Rings = 00 to 20
Special Functions
Settings Result
Enable
Disable
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 514 + 1 + ENTER Call Back
ENTER + 514 + 2 + ENTER Secretary Override
ENTER + 514 + 3 + ENTER Real-Time Reporting
ENTER + 514 + 4 + ENTER Battery Voltage Report
ENTER + 514 + 5 + ENTER Do Not Report Event Reporting Failure
ENTER + 514 + 6 + ENTER Do Not Report Incorrect Password
ENTER + 514 + 7 + ENTER Periodic Test Only By Phone
Partition A monitoring account
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 15 + 0 + ACCOUNT
+ ENTER
Note:
Account = 0000 to 9999
Partition B monitoring account
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 15 + 1 + ACCOUNT
+ ENTER
Note:
Account = 0000 to 9999
Generated DTMF Level
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 18 + SIGNAL + ENTER
Note:
DTMF Signal Level: Signal = 0 to 2
Number of Attempts to Report Events
Settings Result
ENTER + INSTALLER PASSWORD
Factory default: 9090
ENTER + 13 + ATTEMPTS + ENTER
Note:
Attempts: 1 to 9
Communication Priority
Settings Result
Enable
Disable
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 19 + 0 + ENTER Communication Priority will be Ethernet
ENTER + 19 + 1 + ENTER Communication Priority will be GPRS or 3G
ENTER + 19 + 2 + ENTER Communication priority will be Ethernet then GPRS or 3G
ENTER + 19 + 3 + ENTER Communication Priority will be GPRS or 3G then Ethernet
Destination Address
Settings Result
ENTER + INSTALLER
PASSWORD
Factory default: 9090
ENTER + 801 + 1 ENTER + IP + ENTER
Note:
Saves the IP Address of the monitoring
company 1.
ENTER + 801 + 2 ENTER + IP + ENTER
Note:
Saves the IP Address of the monitoring
company 2.