P/N 146667999-1 (ML) • REV G • ISS 19AUG19 7 / 52
Green mode
When SW1-5 is set to Remote on, the radar is switched off
during the day mode (with no WT) to reduce current
consumption. The detector is then operating in PIR only mode.
Note: The Day/night line must be connected to the control
panel for this mode to work.
Alarm memory
When SW1-5 is set to Remote on, alarms that occurred during
the night mode are stored in the detector memory. They are
indicated by flashing red LED when the unit switches to day
mode (walk test disabled). The memory is cleared when the
detector switches back to the night mode.
Note: Set SW1-6 to Off to prevent showing the alarm memory
on the LEDs. See “SW1-6: LEDs” on page 6.
LEDs and outputs
To enable LEDs functionality, set SW1-6 to On, otherwise
LEDs are disabled in any condition. See “SW1-6: LEDs” on
page 6 for more details.
Table 6: LEDs and outputs
Dual motion
intruder alarm
Continuously ON Normal blinking (1 Hz)
Specifications
10, 12, 14, 16 m selectable via
SW1-1 and SW1-2
9 high-density mirror curtains
Max microwave output at 1 m
9 to 15 V (12 V nominal)
Peak-to-peak ripple immunity
2.0 to 3.0 m (6.60 to 9.84 ft.)
0.2 to 3.0 m/s (8 in./s to 10 ft./s)
0.1 to 4.0 m/s (4 in./s to 13 ft./s)
Alarm (NC) / Tamper relay
characteristic
Fault relay characteristic
−10 to +55°C (14 to 130°F)
Regulatory information
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
European Union
directives
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of all applicable
rules and regulations, including but not limited to
the Directive 2014/53/EU. For more information
see: www.utcfssecurityproducts.eu
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info
Contact information
www.utcfireandsecurity.com or www.interlogix.com.
For customer support, see www.utcfssecurityproducts.eu