78 I-Wave PE653-PE953 Installation Guide
Copyright © 2010 Intermatic, Inc.
Problem What to do Reference/Procedure
The heater turns OFF but gets
very hot after the pump turns
OFF.
Verify that the heater has
a proper “Time Interval”
programmed for cool
down.
The Fireman Switch Time Interval is defined as the
additional time the pump will run after the heater circuit
(circuit 5) is turned off to make sure the heater is cooled
down before it shuts off.
Refer to “Configuring the Fireman’s Switch Time Interval”
starting on page 46 in this manual.
Problem What to do Reference/Procedure
The System will not respond
to commands from the Hand-
Held Controller
Verify that the Antenna
section is properly installed
on the top portion
If the Antenna section has been removed for installation of
any type of wiring connection, check the following.
Wires are properly wired and routed through the 1.
knockouts in the antenna cover.
Verify that all of the local antenna connector pins on 2.
the PE653 art straight and properly inserting into the
plug on the Antenna section.
Verify that the Antenna Section is completely seated on 3.
the PE653 housing.
Refer to the 4. “Testing Z-Wave Reception” section
starting on page 50.
Problem What to do Reference/Procedure
Water or moisture is visible
inside the screen of the
Hand-Held Controller.
Dry out the Hand-Held
Controller.
Remove the battery cover on the rear of the PE953 1.
Hand Held Controller. Refer to page 57 for instructions.
Gently drain any water remaining in the Hand-Held 2.
Controller.
Place the Hand-Held Controller in a well ventilated 3.
area to dry.
CAUTION: Do not place in direct sunlight.
Insert new batteries when all traces of moisture are 4.
gone from the screen.
NOTE: Be sure to re-install the gasket correctly to create
a water-tight seal. Refer to page 57 for instructions.
If required, follow programming instructions starting on 5.
page 41.
Problem If it doesn’t work Reference/Procedure
The Hand-Held Controller
appears to be “LOCKED UP”.
Power down the Controller
to reset.
Remove the batteries from the PE953 Hand-Held 1.
Controller.
Allow 15 seconds before replacing the batteries. Refer 2.
to page 57 for instructions.
NOTE: Be sure to re-install the gasket correctly to create
a water-tight seal. Refer to page 57 in this manual for
instructions.
If required, follow programming instructions starting on 3.
page 41.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermatic PE653RC Multi Wave and is the answer not in the manual?

Intermatic PE653RC Multi Wave Specifications

General IconGeneral
BrandIntermatic
ModelPE653RC Multi Wave
CategoryControl Systems
LanguageEnglish

Related product manuals