Chapter 7 — Troubleshoot and Maintain the Computer
CV41 Vehicle Mount Computer (Windows Embedded Standard) User Manual 99
Disconnect the UPS Battery
Disconnect the UPS battery when the computer completely stops
responding or when you are shipping the computer to another
location. Because disconnecting may result in data loss, use this
method only if all other recovery methods have failed.
1 Remove the CV41 from the smart dock. For help, see “Remove the
CV41 from the Smart Dock” on page 8.
2 Using a Phillips head screwdriver, remove the two screws that
secure the SIM card access panel.
3 Press the UPS Battery Disconnect button located below the SIM
card slot.
4 Reinstall the SIM card access panel and tighten the screws to a
torque to a value of 4-5 in/lbs.
Once power external power is reconnected to the CV41, the UPS
battery automatically reconnects.