List of Function Parameters
96
Function
Code
Name Description
Factory
Setting
Modify
Serial
No.
P7.19
Output terminal
status at current fault
BIT3 BIT2 BIT1 BIT0
R0 Y
96
P8 Group: Enhanced Function
P8.00 Acceleration time 1 0.1~3600.0s
Depend
on model
O 97
P8.01 Deceleration time 1 0.1~3600.0s
Depend
on model
O 98
P8.02
Jog reference 0.00~P0.04
5.00Hz
O 99
P8.03
Jog acceleration time 0.1~3600.0s
Depend
on model
O 100
P8.04
Jog deceleration time 0.1~3600.0s
Depend
on model
O 101
P8.05
Skip frequency 0.00~P0.04 0.00Hz
O 102
P8.06
Skip frequency
bandwidth
0.00~P0.04 0.00Hz
103
P8.07
Traverse amplitude 0.0~100.0%
0.0% O 104
P8.08
Jitter frequency 0.0~50.0%
0.0% O 105
P8.09
Rise time of traverse 0.1~3600.0s
5.0s O 106
P8.10
Fall time of traverse 0.1~3600.0s
5.0s O 107
P8.11
Auto reset times 0~3
0 O 108
P8.12
Reset interval 0.1~100.0s
1.0s O 109
P8.13
FDT level 0.00~ P0.04
50.00Hz O 110
P8.14
FDT lag 0.0~100.0%
5.0% O 111
P8.15
Frequency arrive
detecting range
0.0~100.0%maximum frequency
0.0% O 112
P8.16
Brake threshold
voltage
115.0~140.0%
Depend
on model
O 113
P8.17
Coefficient of rotation
speed
0.1~999.9%
100.0% O 114