List of Function Parameters
88
Function
Code
Name Description
Factory
Setting
Modify
Serial
No.
P0 Group: Basic Function
P0.00
Control mode
selection
0:Sensorless vector control
1:V/F control
2:Torque control
0
0
P0.01
Run command
source
0: Keypad (LED extinguishes)
1: Terminal (LED flickers)
2: Communication (LED lights up)
0
1
P0.02
UP/DOWN setting
0: Valid, save UP/DOWN value when power
off
1: Valid, do not save UP/DOWN value when
power off
2: Invalid
3: Valid during running, clear when stop.
0 O 2
P0.03
Frequency A
command source
0: Keypad
1: AI1
2. AI2
3: AI1+AI2
4. Multi-Step speed
5: PID
6: Communication
0 O 3
P0.04 Maximum frequency 10.00~400.00Hz 50.00Hz
4
P0.05
Upper frequency limit P0.06~ P0.04
50.00Hz O 5
P0.06
Lower frequency limit 0.00 Hz ~ P0.05
0.00Hz O 6
P0.07
Keypad reference
frequency
0.00 Hz ~ P0.04
50.00Hz O 7
P0.08
Acceleration time 0 0.0~3600.0s
Depend
on model
O 8
P0.09
Deceleration time 0 0.0~3600.0s
Depend
on model
O 9
P0.10
Running direction
selection
0: Forward
1: Reverse
2: Forbid reverse
0
10
P0.11 Carrier frequency 1.0~15.0kHz
Depend
on model
O 11
P0.12
Motor parameters
autotuning
0: No action
1: Rotation autotuning
2: Static autotuning
0
12