Goodrive170-PV Series Solar Pump Inverter Function parameter list
-36-
Function
code
Name
Description
Default
Modify
62: Full-water pre-alarm (A-tF)
63: Empty-water pre-alarm (A-tL)
The inverter decelerates to stop when
encountering the following faults:
(SPI): Phase loss on input side
(CE): RS485 communication fault
(EEP): EEPROM operation error
(END): Running time reached
(OL3): Electronic overload
(LL): Underload fault
(tSF): Hydraulic probe damage fault
(E-422): 422 communication fault (boost
module)
Note: The prealarm will be not recorded
into the fault but can be read by Modbus.
P08 group Enhanced functions
Function
code
Name
Description
Default
Modify
P08.28
Auto fault
reset count
010
5
P08.29
Auto fault
reset interval
0.13600.0s
10.0s
6.2 Function parameters special for solar pump
P11 group Protection parameters
Function
code
Name
Description
Default
Modify
P11.00
Protection
against
phase loss
0x0000x011
LED ones place:
0: Software protection against input phase
loss disabled
1: Software protection against input phase
loss enabled
LED tens place:
0: Software protection against output
phase loss disabled
Model