Goodrive170-PV Series Solar Pump Inverter Function parameter list
-37-
Function
code
Name
Description
Default
Modify
1: Software protection against output
phase loss enabled
LED hundreds place: (Reserved)
000111
P11.01
Voltage point
for frequency
drop at
transient
power-off
20.0%120.0%
80.0%
P11.02
Frequency
decrease
ratio at
sudden
power loss
0.00HzP00.03/s
If the bus voltage drops to the sudden
frequency decreasing point due to the
power loss of the grid, the inverter begins
to decrease the running frequency
according to P11.02 to make the motor in
power generation state. The regenerative
power can maintain the bus voltage to
ensure normal running of the inverter until
the recovery of power.
10.00Hz/s
P15 group Functions special for solar inverter
Function
code
Name
Description
Default
Modify
P15.00
Solar
inverter
selection
0: Disable
1: Enable
The value 0 indicates solar control is
invalid, and this function group is not used.
The value 1 indicates solar control is valid,
this function group can be modified.
1
P15.01
Vmpp
voltage
giving
method
0: Voltage
1: Max. power tracking
The value 0 indicates using the voltage
giving method, the reference voltage is
P15.02, and it is a fixed value.
The value 1 indicates the reference voltage
is given by tracking the max. power. The
reference voltage keeps changing until the
1

Questions and Answers: