Goodrive170-PV Series Solar Pump Inverter Function parameter list
-20-
6 Function parameter list
"○" indicates that the value of the parameter can be modified when the inverter is in
stopped or running state.
"◎" indicates that the value of the parameter cannot be modified when the inverter is in
running state.
"●" indicates that the value of the parameter is detected and recorded, and cannot be
modified.
Note: The inverter automatically checks and constrains the modification of parameters,
which helps prevent incorrect modifications.
6.1 Function parameters related to control
P00 group Basic functions
0: SVC mode 0
No need to install encoders. Applicable to
scenarios with requirements for low
frequency, great torque, and high speed
control accuracy. Relative to SVC mode 1,
SVC mode 0 is more applicable to the
scenarios requiring small power.
1: SVC mode 1
Applicable to high-performance scenarios,
featuring high rotation and torque accuracy,
without the need to install pulse encoders.
2: Space voltage vector control mode
Applicable to scenarios without demanding
requirements on control accuracy, such as
fan and pump. One inverter can drive
multiple motors.
Note: Before using a vector control mode,
enable the inverter to perform motor
parameter autotuning first.
Channel of
running
commands
Used to select the channel of running
inverter control commands.
The inverter control commands include the
start, stop, forward run, reverse run, jog,