Goodrive170-PV Series Solar Pump Inverter Function parameter list
-21-
and fault reset commands.
0: Keypad (LOCAL/REMOT off)
The commands are controlled through
keypad keys, such as the RUN and
STOP/RST keys. In running state, you can
press both RUN and STOP/RST to enable
the inverter to coast to stop.
1: Terminal (LOCAL/REMOT blinking)
The running commands are controlled
through forward rotation, reverse rotation,
forward jogging, and reverse jogging of
multi-function input terminals.
2: Communication (LOCAL/REMOT on)
The running commands are controlled by the
upper computer in communication mode.
Used to set the max. output frequency of the
inverter. Pay attention to this parameter
because it is the foundation of the frequency
setting and the speed of acceleration (ACC)
and deceleration (DEC).
Setting range: P00.04–400.00Hz
Upper limit of
running
frequency
The upper limit of the running frequency is
the upper limit of the output frequency of the
inverter, which is lower than or equal to the
max. output frequency.
When the set frequency is higher than the
upper limit of the running frequency, the
upper limit of the running frequency is used
for running.
Setting range: P00.05–P00.03 (Max. output
frequency)
Lower limit of
running
frequency
The lower limit of the running frequency is
the lower limit of the output frequency of the
inverter.
When the set frequency is lower than the
lower limit of the running frequency, the lower
limit of the running frequency is used for
running.