Goodrive170-PV Series Solar Pump Inverter Function parameter list
-50-
Function
code
Name
Description
Default
Modify
P19.08
Boost
voltage
loop KI1
If the difference between the bus reference
voltage and actual bus voltage is greater
than 20V, the boost voltage loop uses PI
parameters of this group. Otherwise, the
boost voltage loop uses PI parameters of
the first group.
Setting range: 0.00065.535
0.080
P19.10
Boost
software
version
Once being powered, the boost module
firstly sends its version information to the
inverter side.
0.00
Note:
The duration from when the inverter starts to when it runs at the PI output frequency
lower limit is determined by the ACC time.
Delay time counting follows the rules if multiple fault conditions are met
simultaneously: For example, if all fault conditions of weak light, full water, and
underload are met simultaneously, the delay time for each fault is counted
independently. When the delay time of a fault is reached, the fault is reported. The
delay time counting for the other two faults is kept. If the reported faults is resolved
bu the conditions of the other two faults persist, the delay time counting of the other
two faults continues. If a fault condition is not met during counting, the delay time of
this fault is cleared.