Goodrive170-PV Series Solar Pump Inverter Fault diagnosis and solution
-52-
There is to-ground short
circuit or output phase
loss.
There is strong external
interference.
The overvoltage stall
protection is not enabled.
Check the output wiring.
Check whether there is
strong interference.
Check the setting of related
function codes.
The voltage of the grid is
too low.
Overvoltage stall
protection is not enabled.
Check the grid input power;
Check the settings of
related function code.
The grid voltage is too
low.
The motor rated current
is set incorrectly.
Motor stall or load jumps
violently.
Check the grid voltage;
Reset the rated current of
the motor;
Check the load and adjust
torque boost.
Acceleration is too fast.
The rotating motor is
reset.
The grid voltage is too
low.
The load is too heavy.
The motor power is too
small.
Increase the ACC time.
Avoid the restarting after
stop.
Check the grid voltage.
Select an inverter with
larger power.
Select a proper motor.
Phase loss on the
input side
Phase loss or violent
fluctuation occurred on
input R, S, T.
Check the input power;
Check the installation
wiring.
Phase loss on
output side
Phase loss output occurs
to U, V, W (or the three
phases of the load are
seriously asymmetrical)
Check the output wiring;
Check the motor and
cable.
Rectifier module
overheating
Air duct jam or fan
damage occurs.
Ambient temperature is
too high.
The time of overload
running is too long.
Dredge the vent duct or
replace the fan.
Lower the ambient
temperature.