Goodrive350-19 series VFD Operating
- 195 -
In running
Fault occurred, and the
keypad displayed fault
code
Figure out the fault
cause based on the
fault code
Figure out the most possible
cause according to P07.33–
P07.40
Run again
Proper running
Rule out
fault based on
corresponding
solutions
Consult with INVT
Y
N
N
Y
Related parameter list:
Function
code
Name
Description
Default
value
P07.27
Type of present fault
0: No fault
1: Inverter unit U phase protection (OUt1)
2: Inverter unit V phase protection (OUt2)
3: Inverter unit W phase protection
(OUt3)
4: Overcurrent during acceleration (OC1)
5: Overcurrent during deceleration (OC2)
6: Overcurrent during constant speed
(OC3)
7: Overvoltage during acceleration (OV1)
8: Overvoltage during deceleration (OV2)
0
P07.28
Type of the last fault
/
P07.29
Type of the last but one fault
/
P07.30
Type of the last but two fault
/
P07.31
Type of the last but three
fault
/
P07.32
Type of the last but four fault

Table of Contents