Goodrive350-19 series VFD Function parameter list
- 204 -
Function
code
Name
Description
Default
value
Modify
15: Graded multi-step speed
P00.08
Reference object
of B frequency
command
0: Max. output frequency
1: A frequency command
0
P00.09
Combination
mode of setting
source
0: A
1: B
2: (A+B)
3: (A-B)
4: Max. (A, B)
5: Min. (A, B)
0
P00.10
Set frequency via
keypad
When A and B frequency commands are set by
keypad, the value is the initial digital set value of
the VFD frequency.
Setting range: 0.00 HzP00.03 (Max. output
frequency)
50.00Hz
P00.11
Acceleration
time 1
Acceleration time is the time needed for
accelerating from 0Hz to Max. output frequency
(P00.03).
Deceleration time is the time needed from
decelerating from Max. output frequency (P00.03)
to 0Hz.
Goodrive350-19 series VFD defines four groups of
acceleration and deceleration time, which can be
selected via multi-function digital input terminals
(P05 group). The acceleration/deceleration time of
the VFD is the first group by default.
Setting range of P00.11 and P00.12: 0.03600.0s
Model
depended
P00.12
Deceleration
time 1
Model
depended
P00.13
Running direction
0: Run in default direction
1: Run in reverse direction
2: Reverse running is prohibited
0