The password is needed when enter
into the interface of “Set power”. Get the
password from the supplier if necessary.
There are 3 submenus: ①P-Lmt Mode:
invalid (limited power function is
invalid),auto (special for single
phase) ,manual (set the limit of output
value manually); ② LmtPower: this
function is only valid when the P-Lmt
Mode is manual, the percentage is that
of the rated power and the setting range
is from 10% to 100%; ③p.Factor:
includes normal model (default value
“1”), current advanced mode and
current hysteresis mode and the setting
rage is -0.9-0.99.
(the machine of three phase only has
the function of ③)
This function is only valid for single
phase inverters. The password is
needed when enter into the personal
interface. Get the password from the
supplier if necessary. It can set MPPT
starting voltage from 120V to 160V
under the submenu of ”MPPT start volt”.