Page #35 background image
SPC Series Solar Pump Inverter Function parameter list
-31-
Function
code
Name
Description
Default
Modify
menu if you enter an incorrect password.
Please remember your password and
save it in a secure place.
After you exit the function code editing
interface, the password protection
function is enabled within 1 minute. If
password protection is enabled,
"0.0.0.0.0" is displayed when you
press the PRG/ESC key again to enter
the function code editing interface. You
need to enter the correct user password
to enter the interface.
Note: Restoring the default values may
delete the user password. Exercise
caution before using this function.
P07.01
Parameter
copy
Used to set the parameter copy mode.
0: No operation
1: Upload parameters from the local
address to the keypad
2: Download parameters (including motor
parameters) from the keypad to the local
address
3: Download parameters (excluding
group P02) from the keypad to the local
address
4: Download parameters (only including
group P02) from the keypad to the local
address
Note: After any operation among 14 is
complete, the parameter restores to 0.
The upload and download functions are
not applicable to group P29.
0
P07.02
Function of
QUICK/JOG
Ones place: Function of QUICK/JOG
0: No function
15: Reserved
6: Switch command channels in
sequence
6