SPC Series Solar Pump Inverter Function parameter list
-32-
Function
code
Name
Description
Default
Modify
Tens place: Reserved
P07.03
Sequence of
switching
running-comm
and channels
by pressing
QUICK/JOG
When P07.02=6, set the sequence of
switching running-command channels by
pressing this key.
0: Keypad→Terminal→Communication
1: Keypad←→Terminal
2: Keypad←→Communication
3: Terminal←→Communication
1
P07.04
Stop function
validity of
STOP/RST
Used to specify the stop function validity
of STOP/RST. For fault reset,
STOP/RST is valid in any conditions.
0: Valid only for keypad control
1: Valid both for keypad and terminal
control
2: Valid both for keypad and
communication control
3: Valid for all control modes
3
P07.12
Inverter
temperature
0100.0°C
P07.13
Control board
software
version
1.00655.35
P07.21
Factory bar
code 1
0x00000xFFFF
P07.22
Factory bar
code 2
0x00000xFFFF
P07.23
Factory bar
code 3
0x00000xFFFF
P07.24
Factory bar
code 4
0x00000xFFFF
P07.25
Factory bar
code 5
0x00000xFFFF
P07.27
Present fault
type
0: No fault
13: Reserved
4: Overcurrent during acceleration (OC1)
5: Overcurrent during deceleration (OC2)
6: Overcurrent during constant speed
P07.28
Last fault type
P07.29
2nd-last fault
type