-244-
Display
Fault name
32-bit fault code(16-bit Error
Code+16-bit additional message)
Er02-d
Encoder faultEEPROM data check error
7300-020Dh
Er03-0
Current sensor faultU phase IGBT fault
7300-0300h
Er03-1
Current sensor faultV phase IGBT fault
7300-0301h
Er03-2
Current sensor faultW phase IGBT fault
7300-0302h
Er04-0
System initialization fault
FF01-0400h
Er05-1
Setting faultMotor model error
FF01-0501h
Er05-2
Setting faultMotor and drive model error
FF01-0502h
Er05-3
Setting faultSoftware limit setting error
FF01-0503h
Er05-4
Setting faultHoming mode setting fault
FF01-0504h
Er05-5
Setting faultPosition control overflow fault
FF01-0505h
Er07-0
Regeneration discharge overload fault
7100-0700h
Er08-0
Analog input overvoltage faultAnalog input 2
5441-0800h
Er08-1
Analog input overvoltage faultAnalog input 3
5442-0801h
Er08-2
Analog input overvoltage faultAnalog input 3
5443-0802h
Er09-0
EEPROM faultRead-write fault
5530-0900h
Er09-1
EEPROM faultdata check fault
5530-0901h
Er10-0
Hardware faultFPGA fault
5544-0A00h
Er10-1
Hardware faultCommunication card fault
5544-0A01h
Er10-2
Hardware faultGrounding short circuit fault
5544-0A02h
Er10-3
Hardware faultExternal input fault
5544-0A03h
Er10-4
Hardware faultEmergency stop fault
4458-0A04h
Er10-5
Hardware fault485 communication fault
4458-0A05h
Er11-0
Software fault-Motor control task re-entry
6100-0B00h
Er11-1
Software faultReentrant cycle mission
6100-0B01h
Er11-2
Software faultIllegal operation
6100-0B02h
Er12-0
IO faultRepeat digital input distribution
FF01-0C00h
Er12-1
IO fault-Repetitive analog input distribution
FF01-0C01h
Er12-2
IO faultPulse input frequency is too high
FF01-0C02h
Er13-0
Main circuit overvoltage fault
3110-0D00h
Er13-1
Main circuit undervoltage fault
3120-0D01h
Er14-0
Undervoltage control power fault
5200-0E00h
Er17-0
Drive overload fault
FF01-1100h
Er18-0
Motor overload fault
2310-1200h
Er18-1
Motor overtemperature fault
2310-1201h
Er19-0
Speed faultOverspeed fault
7180-1300h
Er19-1
Speed fault-FWD overspeed fault
7180-1301h
Er19-2
Speed fault-REV overspeed fault
7180-1302h
Er19-3
Speed fault- Overspeed parameter setup error
7180-1303h