Event description
A complete description of the event is reported. Whenever possible, depending on the event, additional
parameters are reported.
In case of a diagnostic event, an internal error code is also added, useful for the purpose of debug. If the
diagnostic event disappears, the label “(Disappearing)” is reported as an additional parameter.
Examples
Detection access (field #3, 1300 mm/40°)
System configuration #15
CANERROR (Code: 0x0010) COMMUNICATION LOST
CANERROR (disappearing)
7.2.5 Log file example
Event logs of ISC NID UP304 updated 2020/11/18 16:59:56
[Section 1 - Event logs]
380 2020/11/18 16:53:49 [ERROR] SENSOR#1 CANERROR (Disappearing)
375 2020/11/18 16:53:44 [ERROR] SENSOR#1 CANERROR (Code: 0x0010) COMMUNICATION LOST
356 2020/11/18 16:53:25 [INFO] CONTROL UNIT System configuration #16
30 2020/11/18 16:53:52 [ERROR] SENSOR#1 ACCELEROMETERERROR (Disappearing)
27 2020/11/18 16:47:56 [ERROR] SENSOR#1 ACCELEROMETERERROR (Code: 0x0010) TILTANGLEERROR
5 2020/11/18 16:47:30 [ERROR] SENSOR#1 Signal error (Code: 0x0012) MASKING
0 2020/11/18 16:47:25 [INFO] CONTROL UNIT Dynamic configuration #1
0 2020/11/18 16:47:25 [INFO] CONTROL UNIT System Boot #60
92 Rel. 0 d 00:01:32 [INFO] CONTROL UNIT Detection exit (field #2)
90 Rel. 0 d 00:01:30 [INFO] CONTROL UNIT Detection exit (field #1)
70 Rel. 0 d 00:01:10 [INFO] SENSOR#1 Detection access (field #2, 3100 mm/20°)
61 Rel. 0 d 00:01:01 [INFO] SENSOR#1 Detection access (field #1, 1200 mm/30°)
0 Rel. 0 d 00:00:00 [INFO] CONTROL UNIT Dynamic configuration #1
0 0 d 00:00:00 [INFO] CONTROL UNIT System Boot #61
[Section 2 - Diagnostic events log]
380 Rel. 0 d 00:06:20 [ERROR] SENSOR #1 CANERROR (Disappearing)
375 Rel. 0 d 00:06:15 [ERROR] SENSOR #1 CANERROR (Code: 0x0010) COMMUNICATION LOST
356 Rel. 0 d 00:05:56 [INFO] CONTROL UNIT System configuration #16
30 Rel. 0 d 00:00:30 [ERROR] SENSOR #1 ACCELEROMETERERROR (Disappearing)
27 Rel. 0 d 00:00:27 [ERROR] SENSOR #1 ACCELEROMETERERROR (Code: 0x0012) TILTANGLEERROR
5 Rel. 0 d 00:00:05 [ERROR] SENSOR #1 Signal error (Code: 0x0014) MASKING
7. Maintenance and troubleshooting
LBK System Series| Instruction manual v1.2 SET 2021|SAF-UM-LBKBus-en-v1.2|© 2020-2021 Inxpect SpA
77