Inxpect LBK Series - 7.3 INFO Events (System Boot, Configuration, Reset)

Inxpect LBK Series
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
l LEVEL 1:the events are logged in a single field at control unit level and the additional information are:
detection field, detection distance (in mm) in access, and detection field at exit.
Format:
CONTROL UNIT Detection access (field #n, distance mm)
CONTROL UNIT Detection exit (field #n)
l LEVEL 2 / LEVEL 3 / LEVEL 4 The events are logged:
o
in a single field at control unit level and the additional information are: detection field, detection
distance (in mm) in access, and detection field at exit
o
at sensor level and the additional information read by the sensor are: detection distance (in mm) in
access, and detection field at exit.
Format:
CONTROL UNIT #k Detection access (field #n, distance mm)
SENSOR #k Detection access (distance mm)
CONTROL UNIT Detection exit (field #n)
SENSOR #k Detection exit
7.3 INFOevents
7.3.1 System Boot
Every time the system is powered up, the event is logged reporting the incremental count of the boot from the
beginning of the life of the device.
Format: System Boot #n
Example:
0 2020/11/18 16:47:25 [INFO] CONTROL UNIT SYSTEMBOOT #60
7.3.2 System configuration
Every time the system is configured, the event is logged reporting the incremental count of the configuration from
the beginning of the life of the device.
Format: System configuration #3
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT System configuration #3
7.3.3 Factory reset
Every time a factory reset is required, the event is logged.
Format: Factory reset
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Factory reset
7. Maintenance and troubleshooting
LBK System Series| Instruction manual v1.2 SET 2021|SAF-UM-LBKBus-en-v1.2|© 2020-2021 Inxpect SpA