7.6.2 CAN errors (CANERROR)
Error Meaning
TIMEOUT Timeout on message to sensor/control unit
CROSS CHECK Two redundant messages do not coincide
SEQUENCE NUMBER Message with sequence number different from the expected number
CRC CHECK Packet control code does not match
COMMUNICATION
LOST
Impossible to communicate with the sensor
PROTOCOL ERROR Control unit and sensors have different and incompatible firmware versions
POLLING TIMEOUT Timeout on data polling
7.7 Cleaning and spare parts
7.7.1 Cleaning
Keep the sensor clean and free of any work residues to prevent masking and/or poor functioning of the system.
7.7.2 Spare parts
Part Product code
Sensor LBK-S01
Control unit ISC-B01, ISC-02, ISC-03
7. Maintenance and troubleshooting