IONTECH
®
IT-DS EDI Modules
Troubleshooting Flow Chart - Increase in DC Volts
Page 1 of 1
START HERE
Are any
DC wires Yes Tighten connections
loose?
No
Feed
water temp
drop?
Yes
Increase in DC voltage
is normal
No
Excess
hardness in
EDI reject?
No
Excess
silica in
EDI reject?
No
Does NaCl/NaOH
cleaning help?
No
Call you local service
provider
Yes
Yes
Yes
Acid clean,
reduce EDI feed
hardness and /or
lower EDI recovery
Caustic clean,
reduce EDI feed
silica and/or
lower EDI recovery
Cleaning removed
organics from resin:
review process design
and operation