8.6 All Circuits On (Override) Mode
All Circuits On mode will engage all electrical circuits at the same time. While short circuit sensing is
operational in this mode, if a short circuit is found, the Alpha MUTT
®
will not be able to identify which
circuit is the cause of the short. Open and crossed circuit sensing is not operational in this mode.
On trailers using incandescent bulbs, All Circuits On mode will typically result in an overload because the
amperage draw will exceed the maximum of 20 amps.
All Circuits On mode can be accessed manually, by remote control or via the tablet.
Manually
1. To activate, access as a shortcut setting via the Shortcut
button, or via the function menu which is located as a
submenu in the main system settings.
12-Button Remote Control
1. To activate, press the All Circ. On button.
Tablet
1. To activate, press the All Circ. On button on either Classic View, Remote View or Diagnostics View.
NOTE: Does not work when ABS or Brake Light circuits are selected.