OPERATOR pro - parameters:
1-o
2-o
3-o
4-o
5-o
6-o
7-o
8-o
9-o
10-o
11-o
12-o
The DS1 displays shows the set N. The DS2 display shows the parameter value
1 ÷ 7
1 ÷ 12
1 ÷ 23
1 ÷ 59
0 ÷ 1
0 ÷ 1
1 ÷ 15 min
0 ÷ 1
1 ÷ 34
0 ÷ 5
Day of the week setting
Month setting
Year setting
Hour setting
Minute setting
Registration frequency setting
Software release display
Blast chiller number setting
Daylight-saving time setting
0 = YES
1 = NO
0 = °C
1 = °F
0 = only blast
chilling
1 = blast chilling
+ preservation
1 = Italian
2 = English
3 = French
4 = German
5 = Spanish
Data registration mode selection
Language selection for printing
Temperature unit setting
set n. Range Description
1
1
08
0
0
0
0
15
0
1
1
Default values
DEFROST cycle
1
Press P7 The DS1 displays shows the set N. The DS2 display shows the parameter value
Shock defrosting phase duration 1min / 1h 30 min
set n. Description
Resolution Default values
1min ÷ 2h
Range
DELICATE FREEZING cycle
1-A
2-A
3-A
4-A
5-A
1-M
2-M
3-M
4-M
5-M
Press P3 The DS1 displays shows the set N. The DS2 display shows the parameter value
A = AUTOMATIC mode M = MANUAL mode
Shock freezing air temp. PHASE 1 - S1
Shock freezing air temp. PHASE 2 - S1
Preservation air temp. - S1
Shock freezing cycle core temp. PHASE 1 - S2
Cycle end core temp.- S2
Shock freezing air temp. PHASE 1 - S1
Shock freezing air temp. PHASE 2 - S1
Preservation air temp. - S1
Shock freezing duration PHASE 1
Shock freezing duration PHASE 2
1°C
1°C
1°C
1°C
1°C
1°C
1°C
1°C
1min / 1h
1min / 1h
0°C
-40°C
-19°C
+6°C
-18°C
0°C
-40°C
-19°C
1h
3h
set n. Description
Resolution Default values
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
1min ÷ 8h
1min ÷ 8h
Range
STRONG FREEZING cycle
1-A
2-A
3-A
1-M
2-M
3-M
Press P4 The DS1 displays shows the set N. The DS2 display shows the parameter value
A = AUTOMATIC mode M = MANUAL mode
Shock freezing air temp. - S1
Preservation air temp. - S1
Cycle end core temp.- S2
Shock freezing air temp. - S1
Preservation air temp. - S1
Shock freezing phase duration
1°C
1°C
1°C
1°C
1°C
1min / 1h
-40°C
-19°C
-18°C
-40°C
-19°C
4h
set n. Description
Resolution Default values
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
-50 ÷ +40°C
1min ÷ 8h