17
Preliminary Operations
DescriptionPhase
To be carried out after a long period in which
the blast chillier has been without power
Front panel screen
FIRST TURN ON
CHAMBER PRE-COOLING
3.4. DESCRIPTION AND OPERATION
LED description
Off
DL1
DELICATE CHILLING cycle
not selected
DELICATE CHILLING cycle
selected
Cycle selection standby
DL2
STRONG CHILLING cycle
not selected
STRONG CHILLING cycle
not selected
Cycle selection standby
DL3
DELICATE FREEZING cycle
not selected
DELICATE FREEZING cycle
selected
Cycle selection standby
DL4
STRONG FREEZING cycle
not selected
STRONG FREEZING cycle
selected
Cycle selection standby
DL5 No cycle active Cycle in progress
Cycle start standby /
User parameter
programming
DL8
Data download not in progress
Data download in progress NOT INCLUDED
DL9
DEFROST cycle
not selected
DEFROST cycle
in progress
NOT INCLUDED
On Flashing
Before introducing the product in the chamber,
it is recommended to carry out pre-cooling.
1
Power the blast chiller and leave it at “OFF”
for about 60 minutes.
This way the sump resistance will have time
to heat the compressor.
This avoids breakdown at the first turn-on,
due to returning refrigerant liquid.
1
Start the chosen cycle for at least minutes before
putting the hot food into the blast chiller