4.1 Setting Method
page 22 IGX/IGB Series Operation Manual No. 0202A
4.1 SETTING METHOD
When the power supply is turned OFF,
press the ON/OFF key to turn ON the power, then immediately press the COLUMN key
while all display segments are lit. Then, the set value number of Setting No. 1 appears.
Ä
Ä
IGX Series
IGB Series
1
Change the set value by pressing the ZERO(+) key or TARE(-) key.
When not changing the setting value, just press the SET key.
IGX Series IGB Series
2
or
Ä
3
Select the desired Setting No. by pressing the SET key.
Return to step 2 above.
IGX Series IGB Series
Ä