TR10K009 RE / 02.2016
133
15 Technical data
Mains voltage 230 / 240V, 50/60Hz
Standby Approx. 6W
Protection category Only for dry rooms
Temperature range –20°C to +60°C
Automatic safety cut-out Is automatically taught in for
both directions separately.
End-of-travel position
cut-out/power limit
ō Self-learning, wear-free,
asit has no mechanical
switches.
ō Additionally integrated
travel time limit of
approx.45 s
ō Readjusting automatic
safety cut-out for every
door run.
Rated load See data label
Pull and push force See data label
Motor Direct current motor with hall
sensor
Transformer With thermal protection
Connection ō Simple screw terminal
ō Max. 1.5mm
2
ō For internal and external
buttons with impulse
operation
Special functions ō Operator light,
2-minutelight
ō 2-wire photocell
canbeattached
Emergency release Actuated with pull cord in the
event of a power failure
Remote control ō 2-button hand transmitter,
RSC2 (433.92MHz)
ō Integrated radio receiver
with 6 memory spaces
Door travel speed approx. 10.5cm/s (depending
on door size and weight)
Airborne sound emission
of the garage door
operator
The equivalent continuous
sound pressure level of 70dB
(A-weighted) is not exceeded
at a distance of 3 metres.
Boom ō Two-part
ō With maintenance-free,
patented toothed belt