TCM
SHOP
MANUAL
Loosen
the
injection
pump
fixing
nuts
and
bracket
bolts.
Adjust
the
injection
pump
setting
angle.
To
advance
the
timing
Pivot
the
injection
pump
body
at
the
drive
shaft
toward
the
engine
outside.
To
retard
the
timing
Pivot
the
injection
pump
body
at
the
drive
shaft
toward
the
engine
inside.
Tighten
the
injection
pump
fixing
nuts
and
the
bracket
bolts
to
the
specified
torque.
Remove
the
dial
indicator
and
install
the
bolt
to
the
distributor
head
screw.
Reinstall
the
injection
pipes.
-29-