EasyManua.ls Logo

Ithaca ITHERM 280 - Table 29 Automatic Status Back (ASB) First Byte (Printer Information); Table 30 Automatic Status Back (ASB) Second Byte (Error Information)

Ithaca ITHERM 280
349 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iTherm
®
280 Programmer’s Guide Programming Codes
28-07764 Rev C Page 211
Bit Off/On Hex Decimal Status for Automatic Status Back (ASB)
0 Off 00H <0> Not used; fixed to Off
1 Off 00H <0> Not used; fixed to Off
2 Off 00H <0> Drawer kick-out connector pin 3 low
On 04H <4> Drawer kick-out connector pin 3 high
3 Off 00H <0> On-line
On 08H <8> Off line
4 On 10H <16> Not used; fixed to On
5 - - - Undefined
6 Off 00H <0> Paper is not being fed by the FEED Button
On 40H <64> Paper is being fed by the FEED Button
7 Off 00H <0> Not used; fixed to Off
Table 29 Automatic Status Back (ASB) First Byte (Printer Information)
Bit Off/On Hex Decimal Status for Automatic Status Back (ASB)
0 - - <0> Undefined
1 - - <0> Undefined
2 Off 00H <0> No mechanical error
On 04H <4> Mechanical error occurred
3 Off 00H <0> No Auto-cutter error
On 08H <8> Auto-cutter error occurred
4 Off 00H <0> Not used; fixed to off
5 Off 00H <0> No unrecoverable error
11
On 20H <32> Unrecoverable error occurred
6 Off 00H <0> No temporary abnormality of the print head
temperature (high temperature)
On 40H <64> Temporary abnormality of the print head
temperature (high temperature) occurred
7 Off 00H <0> Not used; fixed to Off
Table 30 Automatic Status Back (ASB) Second Byte (Error Information)
11
The iTherm® 280 can not recover from mechanical errors without flushing the input buffer. All
print data will be lost if a mechanical error occurs.