Programming Codes iTherm
®
280 Programmer’s Guide
Page 214 Rev C 28-07764
Bit Off/On Hexl Decimal Status
0 Off 00H <0> Not used; fixed to off
1 On 02H <2> Not used; fixed to on
2 - - - Undefined
3 Off 00H <0> Paper is not being fed by the FEED
Button
On 08H <8> Paper is being fed by the FEED Button
4 On 10H <16> Not used; fixed to on
5 Off 00H <0> No paper out stop
On 20H <32> Printing stops due to paper out
6 Off 00H <0> No error
On 40H <64> Error occurs
7 Off 00H <0> Not used; fixed to off
Table 37 Off line Status (<n> = 2)
Bit Off/On Hex Decimal Status
0 Off 00H <0> Not used; fixed to off
1 On 02H <2> Not used; fixed to on
2 Off 00H <0> No mechanical error
On 04H <4> Mechanical error occurred
3 Off 00H <0> No auto-cutter error
On 08H <8> Auto-cutter error occurred
4 On 10H <16> Not used; fixed to on
5 Off 00H <0> Unrecoverable error occurred
12
On 20H <32> Recoverable error occurred
6 Off 00H <0> Not used; fixed to off
7 Off 00H <0> Not used; fixed to off
Table 38 Error Status (<n> = 3)
Bit Off/On Hex Decimal Status
0 Off 00H <0> Not used; fixed to off
1 On 02H <2> Not used; fixed to on
2,3 Off 00H <0> Paper low sensor: paper adequate
On (0CH) (<12>) Paper low sensor: paper low
4 On 10H <16> Not used; fixed to on
5,6 Off 00H <0> Paper out sensor: paper adequate
On 60H <96> Paper out sensor: paper not present
7 Off 00H <0> Not used; fixed to off
Table 39 Paper Roll Sensor Status (<n> = 4)
Function Transmit Peripheral Status
ASCII [ESC] u <n>
Hexadecimal 1BH 75H <n>
Decimal <27> <117> <n>
Range n = 0
Description The [ESC] r <n> command transmits peripheral status has been replaced by the
[GS] r command. The iTherm
®
280 return cash drawer status as specified below.
Bit Off/On Hex Decimal Status
12
The iTherm
®
280does not allow buffer recovery on unrecoverable errors. Following the recovery
process will not restore the data buffers.

Table of Contents