iTherm
®
280 Programmer’s Guide Programming Codes
28-07764 Rev C Page 229
Function Transmit maintenance counter
ASCII [GS] g 2 m nl nh:
Hexadecimal 1DH 67H 32H
Decimal <29> <103> <50>
Description Transmits the value of the specified maintenance counter.
• nl, nh specifies the maintenance counter number as (nl + nh x 256)
Counter number Counter [Units] Kind of counter
Hex Decimal
14 20 Number of line feeds: roll paper can be reset
14 20 Number of times energizing head: roll paper
14 20 Number of autocutter operations
14 20 Printer operation time
14 20 Number of line feeds: roll paper cumulative
14 20 Number of times energizing head: roll paper
14 20 Number of autocutter operations
14 20 Printer operation time
• The contents of the maintenance counter are as follows:
Hexadecima
Decimal Amount of data
Header 5FH 95 1 byte
Data 30H-39H 48-57 1-10 bytes
NUL 00H 0 1 byte
• During the transmission of block data values in the maintenance counter, the printer ignores
the real-time commands. Also, the printer does not transmit ASB even when the ASB is
enabled. Therefore, the user cannot confirm changes in the printer status during these periods.
• The counter values may be different from the actual counts depending on time differences at
power off or the occurrence of an error.