5 Commissioning, Startup, Operation, and
Shutdown
5.1 Preparation for startup
WARNING:
Risk of serious physical injury or death. Exceeding any of the pump operating limits (e.g. -
pressure, temperature, power, etc.) could result in equipment failure, such as explosion,
seizure, or breach of containment. Assure that the system operating conditions are within
the capabilities of the pump.
Risk of death or serious injury. Leaking fluid can cause fire and/or burns. Ensure all open-
ings are sealed prior to filling the pump.
Breach of containment can cause fire, burns, and other serious injury. Failure to follow
these precautions before starting the unit may lead to dangerous operating conditions,
equipment failure, and breach of containment.
Risk of explosion and serious physical injury. Do not operate pump with blocked system
piping or with suction or discharge valves closed. This can result in rapid heating and va-
porization of pumpage.
Risk of breach of containment and equipment damage. Ensure the pump operates only
between minimum and maximum rated flows. Operation outside of these limits can cause
high vibration, mechanical seal and/or shaft failure, and/or loss of prime.
WARNING:
Risk of death, serious personal injury, and property damage. Heat and pressure buildup
can cause explosion, rupture, and discharge of pumpage. Never operate the pump with
suction and/or discharge valves closed.
Running a pump without safety devices exposes operators to risk of serious personal in-
jury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
Starting the pump in reverse rotation can result in the contact of metal parts, heat genera-
tion, and breach of containment. Ensure correct driver settings prior to starting any pump.
Precautions
WARNING:
The mechanical seal used in an Ex-classified environment must be properly certified.
5 Commissioning, Startup, Operation, and Shutdown
52 Model NM 3196 i-FRAME Installation, Operation, and Maintenance Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITT Goulds Pumps NM 3196 i-FRAME and is the answer not in the manual?

ITT Goulds Pumps NM 3196 i-FRAME Specifications

General IconGeneral
ModelNM 3196 i-FRAME
CategoryWater Pump
TypeCentrifugal Pump
Connection TypeFlanged
i-FRAMEYes
Seal TypeMechanical Seal

Related product manuals