> Hot water mode
B Select hot water mode.
Economy means that the hot water is permitted to cool slightly before
hot water production starts compared to Comfort. Heating stops at a
slightly lower temperature.
B Change to Comfort if more or hotter hot water is desired.
This setting must be used if electric additional heat is missing or if the
hot water circulation is used, when the temperature in the hot water
circulation is otherwise too low.
> Hot water settings heat pump 1
>> Hot water production
> Hot water settings HP 2
Heat pump 2 has factory setting No for Hot water production. This
value must not be changed.
> Block heating during hot water demand
B Select Yes if the hot water demand must always be satisfied before
the heat demand.
B Select No if hot water production should be interrupted after a certain
time in event of a heat demand.
B In No also set the duration that hot water production may occur for
during the heat demand.
>> Maximum operating time for hot water at heating demand
> Hot water circulation (accessory)
A special circulation pump for hot water, E41.G6, can be installed. It is
subject to time control, i.e., it can be activated during parts of the day.
Due to the circulation, the hot water reaches the tapping place faster.
>> Hot water circulation pump active
B Indicate Yes if there is circulation pump.
Time settings can then be made.
B In Yes, change hot water mode to comfort mode.
>> Time settings
B Set up to four separate intervals.
B To change time: turn the menu dial until the desired time appears.
Push the menu dial to continue to the next setting field.
B Go back to the previous field by using .
B Press the menu dial in the last setting field to save settings
Hot water circulation takes place every day during the set periods.
> Protective anode installed
1)
value set during Start-up
Change the value if there has been a change since start-up.
B Change to No if no anode exists.
Normally, there is an anode in the hot water heater in order to protect
it against corrosion. If the anode breaks, it must be fixed to prevent
the hot water heater from being damaged. The control unit alerts
when the anode is broken.
Factory setting Economy
Alternative Economy/Comfort
Table 88 Hot water mode
In certain countries there are requirements regarding
the lowest hot water temperature in buildings. Check
that the settings in Economy and Comfort mode conform
to the applicable regulations.
Factory setting Yes
Alternative No/Yes
Table 89 Hot water production
Factory setting No
Alternative Yes/No
Table 90 Block the heat
Factory setting 30 min
Lowest value 5 min
Highest value 60 min
Table 91 Operating time hot water
Factory setting No
Alternative No/Yes
Table 92 Hot water circulation pump active
Start time Stop time
00:00 24:00
Table 93 Time settings
Factory setting
1)
Alternative Yes/No
Table 94 Anode installed