Settings
6 720 802 419 (2012/06) en
63
> Additional heat program
This function can be used to set the times between which additional heat
mode is blocked.
>> Activate program
>> View/edit active program
Only displayed if a program has been selected.
>> Outdoor temperature limit for deactivation of time control
Only displayed if a program has been selected.
B Set a suitable temperature for deactivation of time control. -26 °C =
function Off.
If T2 is over set Outdoor temperature limit for deactivation of time
control for 15 minutes, or if Outdoor temperature limit for
deactivation of time control is set to Off, the additional heat will be
blocked by time control as long as Additional heat program is
activated.
If T2 is under set Outdoor temperature limit for deactivation of time
control or if Additional heat program is deactivated the additional heat
will not be blocked by time control.
16.9 Safety functions
• Setting collector circuit in T10
• Setting collector circuit out T11
The settings for collector circuit in/out are:
> Setting collector circuit in T10 /
Setting collector circuit out T11
>> Lowest permitted temperature E21.T10 / Lowest permitted
temperature E21.T11
>> Hysteresis alarm reset
>> Number of warnings before alarm
The number of warnings is calculated during a time period of 180 min.
16.10 General
Among other things, settings for date and time are available here.
> Room sensor settings
>> Show outdoor temperature in room sensor
> Set date
> Set time
B Check and change, if necessary, date and time. These are used by the
control unit to manage the different clock settings, e.g., holiday and
room temperature program.
> Summer/winter time
B Select if there should be automatic change over between summer and
winter time or not (dates according to EU standard).
> Display contrast
B If necessary, change the background light of the control panel.
> Language
B Change language, if desired.
> Country
B Select country.
Here, a different country can be selected than was chosen as part of
the pre-configuration (start-up).
Factory setting No
Alternative No/Yes
Table 150 Activate additional heat program
Factory setting -26 °C (Off)
Lowest value -26 °C
Highest value 20 °C
Table 151 Outdoor temperature limit time control
Factory setting -6,0 °C (T10)
-8.0 °C (T11)
4.0 °C Groundwater (T10)
2,0 °C Groundwater (T11)
Lowest value -10,0 °C
Highest value 20,0 °C
Table 152 Lowest temperature, collector circuit
Factory setting 1.0K
Lowest value 1.0K
Highest value 10.0K
Table 153 Hysteresis
Factory setting 1
Lowest value 1
Highest value 4
Table 154 Number of warnings before alarm
Factory setting No
Alternative Yes/No
Table 155 Show outdoor temperature in the room sensor
Factory setting
Format yyyy-mm-dd
Table 156 Date
Factory setting
Format hh:mm:ss
Table 157 Time
Factory setting Automatic
Alternative Manual/Automatic
Table 158 Summer/winter time.
Factory setting 70%
Lowest value 20%
Highest value 100%
Table 159 Brightness
Language change can also be brought about by holding
down the -button in the standard display for at
least 5 s.