Factory settings
6 720 802 419 (2012/06) en
73
18 Factory settings
18.1 Return to factory settings
The function exists on both customer and installer level. All settings
available to the customer are restored on customer level.
All settings on installer level are restored when the function is used on
installer level. Customer level settings are not affected.
18.2 Factory values
Access level 0 = Customer
Access level 1 = Installer
Room temperature F value Access level
Circuit 1 Heating Type of heating system Underfloor 1
Highest permitted flow temperature T1
80/45 °C 1
Lowest permitted flow temperature T1
10 °C 1
Heat curve
0
Heat curve hysteresis heat pump x
Maximum
Minimum
Time factor
25.0K
4.0K
20.0
1
1
1
Room sensor
Room temperature influence
Acknowledge room sensor
3,0
(Auto)
1
1
Room temperature program Active program
View/edit active program
Room temperature normal
Temperature increase/decrease (no room sensor)
Setting temp. increase/decrease (no room sensor)
> Limit value for left or right end point
> Change when much colder/warmer
> Change when colder/warmer
Room temperature influence (no room sensor)
Room temperature exception
Copy to all heating circuits
HP optimized
20,0 °C
=
0,0 °C
8%
3%
3,0
17,0 °C
No
0
0
0
0
1
1
1
1
0
0
0
Circuit 2, 3... Mixing valve mode Off 1
Type of heating system
Underfloor 1
Highest permitted flow temperature T1
Radiator/Underfloor 80/45 °C 1
Lowest permitted flow temperature T1
10 °C 1
Heat curve
0
Room sensor
As Circuit 1 Heating 0, 1
Room temperature program
As Circuit 1 Heating minus Copy to all heating circuits 0, 1
Regulator settings
P constant
I constant
D constant
Minimum PID signal
Maximum PID signal
Mixing valve running time
Mixing valve fully closed
Mixing valve start closing
1,0
300
0.0
0%
100%
300s
2.0K
2.0K
1
1
1
1
1
1
1
1
General Summer/winter operation Winter operation
Outdoor temperature limit for change over
Delay before change over to winter operation
Delay before change over to summer operation
Direct start limit for winter operation
Automatic
18 °C
4h
4h
13 °C
0
0
1
1
1
Maximum operating time for heating at hot water
demand
20min 1
Minimum outdoor temperature -35 °C 1
Table 169 Factory settings Room temperature