Factory settings
6 720 802 419 (2012/06) en
74
Hot water F value Access level
Acknowledge hot water sensor T3 (Auto) 1
Extra hot water Extra hot water duration
Extra hot water stop temperature
0h
65 °C
0
0
Hot water peak Day of the week
Interval in weeks
Start time
Maximum time
Time for warm-keeping
None
1
3:00
3.0h
1.0h
0
0
0
1
1
Hot water program Active program
View/edit active program
Always hot water 0
0
Hot water mode Economy 0
Hot water settings heat pump x Hot water production Yes/No 1
Block heating during hot water demand No 1
Maximum operating time for hot water at heating
demand
30 min 1
Protective anode installed Yes/No 1
Table 170 Factory settings Hot water
External control F value Access level
Heat pump x External input 1, 2 Invert input No 1
Block additional heat 100% at trigged power guard No 1
Max output additional heat at trigged power guard Off 1
Block compressor x No 0
Block additional heat No 0
Block heating at tripped underfloor temperature limiter No 1
Block heating No 0
Room temperature No (0,0 °C) 0
Block hot water production No 0
Start collector circuit pump No 1
Alarm at low pressure in collector circuit No 1
External input circuit 2,
3...
Invert input No 1
Block heating at tripped underfloor temperature limiter No 1
Block heating No 0
Room temperature No (0,0 °C) 0
Table 171 Factory value External control
Installer F value Access level
General Anti-seizure mode Day of the week
Start time
Wednesday
12:00
1
1
Highest permitted flow temperature T1 Radiator/Underfloor 80/45 °C 1
Operating mode
1
Groundwater
Groundwater
Compressor start delay groundwater
No
15s
1
1
Display light switch off delay
5 min 1
Time for reset of access level
20 min 1
Heat pump x capacity (Start-up) 1
Connected I/O boards Shows which circuit boards are
connected and their program version
1
Compressor working area Outdoor stop function activated No 1
Circulation pumps Heating circuit pump G1 Operation alternative Continuous 1
Heat carrier pump G2
Operation alternative
Pump speed E2x
> Fixed pump speed
> Temperature difference heat transfer fluid when heating
> Temperature difference heat transfer fluid when hot water
> Pump speed at no demand Regulator settings
> P constant
> I constant
Continuous
Auto
7K
7K
10%
3.0
300.0
1
1
1
1
1
1
1
Collector circuit pump G3
Operation alternative Automatic 1
Table 172 Factory settings Installer