JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
||
|
JA-14K(R) Security System Control Panel 39 / 72 MNX22101
Installation name (see the Communication setup tab):
Time (of event occurrence), Event (see table).
Event source (see the Devices/Name or User/Name tab), Section (where the event occurred);
Time (time and date of sending)
Example of a sent SMS:
JA-10 (installation name)
17:01:10, Delayed alarm (event time, event)
Door magnet, Ground floor (detector name, section name)
17:01:25, Instant alarm (event time, event)
Staircase movement, Upstairs (detector name, section name)
Time 17:01 22.7. (time of sending)
9.13 System acoustic indication
Acoustic indication of the system can indicate not only alarm status but also inform about other statuses or
status changes. For an acoustic indication overview see the following tables:
Acoustic indication by keypad / reader:
Button pressing confirmation
Functional button activation, setting a section or switching on a PG
Functional button deactivation, unsetting a section or switching off a PG
Section unsetting with alarm memory indication
Continuous beeping
Alarm
Acoustic indication by indoor / outdoor sirens:
One short beep
Two short beeps
Three short beeps
Section unsetting with alarm memory indication
PG status indication – quick beeping
Permanent slow beeping
PG status indication – slow beeping
Continuous squeaking
Entrance delay
PG status indication – permanent squeaking
Acoustic indication of fire detectors (smoke, temperature, gas):
Fire alarm
9.14 Disabling and blocking options
9.14.1 Disabling
Before you set the system a situation can occur where a device is necessary to be intentionally bypassed from
guarding (for instance a garage because of some construction activity or leaving a dog inside a usually