EasyManua.ls Logo

jablotron JA-14KR - CID and SIA Codes

jablotron JA-14KR
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JA-14K(R) Security System Control Panel 60 / 72 MNX22101
10.11.3 JA-10 CID and SIA codes
CID
SIA
Event EN
Report category
1101
QA
Health problem
Burglary
1110
FA
Fire alarm
Fire
1118
FG
Unconfirmed fire alarm
Fire
1120
PA
Panic alarm
Panic
1130
BA
Instant alarm
Burglary
1133
BA
24H alarm
Burglary
1134
BA
Delayed alarm
Burglary
1138
BG
Unconfirmed alarm
Burglary
1144
TA
Tamper of device
Tamper
1151
GA
Gas leak
Fire
1154
WA
Flood alarm
Tamper
1174
UA
Not used
Special reports
1175
UA
Not used
Special reports
1176
UA
Not used
Special reports
1130
UA
Keybox
Special reports
1300
ET
Fault
Faults and service events
1301
AT
AC loss
Burglary
6301
AT
AC loss longer than 30 min (from FW 10 and higher)
Burglary
1302
YT
Low Battery in control panel
Faults and service events
1305
RR
System boot
Faults and service events
1306
LB
Entering service mode
Faults and service events
1308
RE
System shutdown
Faults and service events
1314
YG
ARC setting erased
Uncategorised
1344
XQ
RF jamming / RF interference
Faults and service events
1350
YC
Event to ARC not delivered
Uncategorised
1354
YS
Event to ARC was not delivered in pre-set time
Faults and service events
1384
XT
Low Battery in device
Faults and service events
1401
OP
Unset
Setting / Unsetting
1402
OG
Unset partially
Setting / Unsetting
1406
BC
Alarm cancelled by user
Burglary
1407
OQ
Unset remotely
Setting / Unsetting
1412
LF
Remote access
Uncategorised
1416
LS
Configuration saved
Uncategorised
1454
CI
Section with no movement
Faults and service events
1455
CI
Unsuccessful setting
Uncategorised
1461
JA
Code breaking attempt exceeded
Tamper
1521
BL
Siren mute
Uncategorised
1570
EB
Device bypass (Disabled)
Uncategorised
1572
TB
Tamper bypass
Faults and service events
1573
BB
Activation bypass
Faults and service events
1574
UB
Bypass of a section (Disabled)
Uncategorised
1578
UO
Fault bypass
Faults and service events
1601
RX
Manual test
Faults and service events
1602
RP
Periodic test / Link test
Uncategorised
1625
JT
Reset of time
Uncategorised
1661
RC
PG1 ON
PG controls
1662
RC
PG2 ON
PG controls
1663
RC
PG3 ON
PG controls
1664
RC
PG4 ON
PG controls
3101
QR
Health troubles (deactivation)
Burglary
3110
FR
Fire alarm (deactivation)
Fire
3118
FG
Unconfirmed fire alarm (deactivation)
Fire
3120
PR
Panic (deactivation)
Panic
3130
BR
Instant alarm (deactivation)
Burglary
3133
BR
24hr alarm (deactivation)
Burglary
3134
BR
Delayed alarm (deactivation)
Burglary
3138
BG
Unconfirmed alarm (deactivation)
Burglary
3144
TR
Tamper (deactivation)
Tamper
3151
GR
Gas leak (deactivation)
Fire

Table of Contents