22 J‐S180F/J‐S199F
TechnicalData
Specificaons
Model J‐SN180F,J‐SP180F J‐SN199F,J‐SP199F
MinimumGasConsumponBtu/h
9,900(NG)
10,300(LPG)
MaximumGasConsumponBtu/h 180,000
199,000(NG)
190,000(LP)
Hotwatercapacity(Min‐Max)*
0.26‐7.5GPM
(1‐28.5L/min)
0.26‐9.4GPM
(1‐35.5L/min)
TemperatureSeng(nocontroller) 120°F(49°C)or140°F(60°C)
MaximumTempSeng(
residenal)
seeTemperatureRangesformoreinformaon
Selectableat120
°F(49°C)orat140°F(60°C)
MinimumTemperatureSeng 98°F(37°C)
Weight 51lb(23kg) 53lb(24kg)
EnergyFactor 0.82
Noiselevel 49dB(excludingstartuporshutdown)
ElectricalConsumpon
Normal 76W 83W
Standby 2W
An‐frostProte
con 184W
By‐PassControl Fixed Electronic
GasSupplyPressure
NaturalGas 5.0‐10.5inchW.C.
Propane 8.0‐13.5inchW.C.
TypeofAppliance DirectVent,Temperaturecontrolledconnuousflowgashotwatersystem.
Connecons GasSupply:3/4"MNPT,ColdWaterInlet:3/4"MNPT,HotWaterOutlet:3/4"MN
PT
IgnionSystem DirectElectronicIgnion
ElectricConnecons Appliance:AC120Volts,60Hz.RemoteControl:DC12Volts(Digital)
WaterTemperatureControl SimulaonFeedforwardandFeedback.
WaterSupplyPressure MinimumWaterPressure:20PSI(Recommended30‐80PSIformaximumperformance)
MaximumWaterSupplyP
ressure 150PSI
TemperatureControlCable Non‐PolarizedTwoCoreCable(Minimum22AWG)
EnergyStarQualified Yes
Cerfiedforinstallaoninmanufactured
(mobile)homes
Yes
*Minimumflowmayvaryslightlydependingonthetemperaturesengandtheinletwatertemperature.
Minimumacvaonflowis0.4GPM(1.5L/min).
Ourproductsareconnuallybeingupdatedandimproved;therefore,specificaons aresubjecttochange
withoutpriornoce.
Themaximuminl
etgaspressuremustnotexceedthevaluespecifiedbythemanufacturer.Theminimumvalue
listedisforthepurposeofinputadjustment.