V03
JCAII 4
·Deletes accumulation records
·Display year, date, time
·Go back to previous parameter
·Recalls and displays the accumulated data
·Selects/ sets the Hi Value of weight or piece
·change the next content of parameter
·Selects the Lo value of weight or piece
·Changes to previous content of parameter
·Tare
Give up any setting and return to normal weighing
·Call up unit weight ID
·Enable / switch on relay output function under HI/LO setting.
·Print
·Disable/ switch off relay output function under HI/LO setting.
5. Analog Section
Input sensitivity 1~4mV/V
Zero adj. Range 20% FS
A/D conversion rate 10 times per second.
Load cell excitation 5V DC
Number of load cells. up to 4x350 ohm loadcells
Resolution. 1/30,000
6. Setting mode
1. Under the weighing mode, long press key for 3 seconds to enter basic parameter setting
mode.
2. Press or to switch between parameters from P-00 to P-07
3. Press key or to step through all the available setting options.
4. Press key to save the setting and return to weighing mode.